I'm 100% convinced that temperature is not the cause. I've seen the problem on at least: 3 PC platforms (a year ago) SOEKRIS Net 4501 (1 month ago) SOEKRIS Net 4801 (Now) No components where reused. Also the PC installation was placed in an air-conditioned serverroom. I still have a hunch that the problem is related to packet fragmentation and/or ICMP (which is different from site to site). For now i've set up rules to block all ICMP traffic for the problem site and the uptime is now 2 days, 18:16. Since installation (1,5 months ago) I've seen 2 days typical uptime, with a minimum extreme of 1 hour and a maximum extremme of 11 days. I hope this experiment will aid in pinpointing the problem. If anyone has tries this already (blocking all ICMP) i'd very much like to hear if that solved the problmes. I have several sites running monowall without problems. The traffic pattern/contents is more or less the same on all sites. However the LAN equipment connected is very different. BR Søren Vanggaard Jensen >From: Rolf Kutz <kutz at netcologne dot de> >To: m0n0wall at lists dot m0n0 dot ch >Subject: Re: [m0n0wall] Version 1.22 freeze >Date: Mon, 3 Jul 2006 00:32:36 +0200 > >* Quoting Soren Vanggaard Jensen (svanggaard at hotmail dot com): > > > A year ago i had a problem with a older version of monowall. The same > > problem went on for more than 4 months and for 3+ hardware setups. Back > > > > Right now i have a monowall installation that freequently freezes. This > >Maybe this is because it's summer at the moment >and the higher temperatures make some systems >unstable. > >regards, Rolf > >--------------------------------------------------------------------- >To unsubscribe, e-mail: m0n0wall dash unsubscribe at lists dot m0n0 dot ch >For additional commands, e-mail: m0n0wall dash help at lists dot m0n0 dot ch > |